BL Touch Probe Swapping
BL Touch Probe Swap
Remove the Toolhead and BL Touch mount from the Printer
- Disconnect the cables from the following ports
- Undo the Two screws on the Top of the Toolhead as shown in the picture
- Remove the Back screw from the toolhead, let us know if you don't have a thumbscrew
- After the Backscrew has been removed, the Toolhead will detach from the mount.
With the Toolhead and BL Touch Removed, let's move to remove the BL Touch Probe
Be Careful, the probe is very fragile- Remove the Hex Screw from the BL Touch's Chamber using a 2.5 mm hex key
- With the chamber removed, let's remove the probe from the chamber, it should just slide out.
- Remove the threaded stud and pop the probe out by using a smaller hex key
- Insert the new probe and screw the threaded stud back in
- Reattach the BL touch into its chamber and screw the bolts back into the BL Touch Mount
With the BL Touch Probe Replaced, reattach the toolhead to the printer. Just reverse the initial steps to remove the toolhead from the Printer
- With the toolhead reattached and everything plugged in, let's turn the printer on, and Select: Menu → Leveling → Self-Test
- Select Self-Test, and the Probe should extend and retract 10 times in total.